Page 68 - Ver_216M_1
P. 68
Breaking the module to build it stronger






Typhoon 4.0

UPPER TABLE POSITION :
WORK SPACE 53.8”w x 54”d x 34.6”h (1366 x 1372 x 879mm)
LOWER TABLE POSITION :
53.8”w x 54”d x 53.6”h (1366 x 1372 x 1362mm)
OUTER 69.2”w x 78.8”d x 103.9”h
DIMENSIONS (1759 x 2003 x 2640mm)

TEMPERATURE +200 °C TO -100 °C, +250°C TO -100°C
RANGE


THERMAL RAMP 70 °C - 100 °C/min average

TABLE SIZE 48” x 48” (1220 x 1220mm)
5 - 75 gRMS (Bare Table)
ACCELERATION TABLE CAPACITY 600 lbs (272kg)
Recommended
TABLE CAPACITY 600 lbs (272kg)
Recommended
POWER 380V, 400V, 440V, 480V, 3Φ , 50/60Hz, 100A
REQUIREMENTS

ACTUATORS 12 Lubricant free

method used to identify the limiting failure
A Highly Accelerated Life Test (HALT), is a HALT
stress testing methodology for accelerating
and the stresses at which these failures occur.
product reliability during the engineering
development p rocess. It is commonly the failure will be detected. The failure may only
The major advantages of HALT are: a) it can
performed to identify and help resolve design be conducted during the development phase
be present while the stress is applied and
weaknesses with progressively more severe may n
of a product in order to weed out design ot cause permanent degradation
problems and marginal components thereby
environmental stresses. Another feature that would be apparent after the stress is
of HALT testing is that it characterizes the removed. All failures during HALT testing are
eliminating costs for warranty returns; b) it
equipment under stress, and identifies also is conducted as internal qualification
subject to failure analysis and root cause
the equipment's safe operating limits and testing which significantly reduce costs prior to
analysis.
sending the equipment for formal qualification.
design margins. Some common forms of
failure acceleration for industrial products
During a HALT test the tested equipment has to
are power cycling, temperature cycling and
random vibration. HALT serves to improve
be functional and operational while monitored so
that if the equipment fails while being stressed,
the reliability of a product and is an empirical
67